Inputs

All of FLUME’s keys are in the flume namespace. Every key has a range check that stops the run with a message naming the key; no value is clamped. An unknown key in the flume namespace stops the run at start-up. Lengths are in metres, times in seconds, elevations on one vertical datum (Vertical datum).

Grid

Key

Type

Default

Meaning and allowed values

flume.n_cell

2 integers

required

Cells in x and y. Each from 1 to 230.

flume.prob_lo

2 reals

0 0

Lower corner of the domain. Finite.

flume.prob_hi

2 reals

required

Upper corner. Finite and greater than flume.prob_lo.

flume.periodic

2 integers

0 0

Periodic in x and in y. Each 0 or 1.

flume.max_grid_size

integer

64

Largest box edge, in cells. From 1 to 2147483647.

In each direction the corners must be at most one eighth of the largest floating-point number in magnitude, and the cell size must be a normal number of at least machine epsilon times the larger corner (Single precision and large coordinates).

Time loop and scheme

Key

Type

Default

Meaning and allowed values

flume.stop_time

real

none

Time at which the run stops. Finite, at least 0. Held in double precision in every build.

flume.max_step

integer

none

Largest number of steps. From 0 to 2147483647.

flume.cfl

real

0.5

CFL number (Time step). Greater than 0 and at most 1; at most 0.5 with flume.order = 2.

flume.order

integer

1

Order of the scheme in space and time, 1 or 2 (Discretization). Order 2 costs about twice the work per step.

flume.gravity

real

9.81

Acceleration of gravity, m/s2. Finite, greater than 0.

flume.dry_depth

real

1e-6

Depth at or below which water counts as dry (Wetting and drying). Finite, at least 0. In single precision raise it for beds above about 10 m, where the bed is rounded to more than the default.

Output

Key

Type

Default

Meaning and allowed values

flume.plot_file

string

plt

Plotfile name prefix. Not empty.

flume.plot_int

integer

0

Steps between plotfiles, from 0 to 2147483647. The first and the last state are always written.

Boundaries

A side of a direction that is not periodic is a wall, except where a segment gives it another type (Boundary conditions).

Key

Type

Default

Meaning and allowed values

flume.bc.segments

strings

none

Names of the segments, each once; letters, digits and _.

flume.bc.<name>.side

string

required

xlo, xhi, ylo or yhi; not a periodic side.

flume.bc.<name>.type

string

required

wall or outflow. discharge and stage are reserved and stop the run.

flume.bc.<name>.range

2 reals

whole side

From and to along the side. Finite, ordered, inside the domain. The segment takes the boundary cells whose centre is at the first value or above and below the second: at least one, and no cell in two segments.

Bed and buildings

Key

Type

Default

Meaning and allowed values

flume.bed.file

string

none

ESRI ASCII grid of the bed elevation (Raster files), interpolated bilinearly. Not with any other flume.bed key.

flume.buildings.file

string

none

ESRI ASCII grid of building heights above the bed, or a mask with flume.buildings.height. Values at least 0; a cell above 0 is a building (Buildings).

flume.buildings.height

real

none

Height given to every building cell of a mask. Finite, greater than 0. Needs flume.buildings.file.

flume.bed.elevation

real

0

Bed elevation at the lower corner of the domain. Finite.

flume.bed.slope

2 reals

0 0

Slope of the plane bed in x and y (rise over run). Finite.

flume.bed.continue_slope

integer

0

1 continues the plane across periodic sides, an endless inclined channel; 0 repeats the bed. 1 needs a periodic direction with a slope.

flume.bed.bowl_depth

real

0

Depth of a paraboloid bowl at the centre of the domain; negative for a mound. Finite. Needs flume.bed.bowl_radius. For tests.

flume.bed.bowl_radius

real

none

Radius at which the bowl crosses the plane. Finite, greater than 0. Needs a flume.bed.bowl_depth that is not 0.

flume.bed.noise

real

0

Amplitude of a fixed pseudo-random roughness of the bed. Finite, at least 0. For tests.

Friction

Key

Type

Default

Meaning and allowed values

flume.friction.manning

real

0

Manning coefficient, s/m1/3, the same in every cell. Finite, at least 0; 0 is no friction. Typical: 0.01 to 0.02 smooth concrete, 0.03 natural channel, 0.05 to 0.1 vegetated floodplain.

flume.friction.manning_file

string

none

ESRI ASCII grid of the coefficient; each cell takes the raster cell that holds its centre. Values at least 0. Not with flume.friction.manning.

Rain

Key

Type

Default

Meaning and allowed values

flume.rain.type

string

none

none, constant, hyetograph (Rain), gridded or moving_cell (Rain that varies in space). microphysics is reserved and stops the run.

flume.rain.rate

real

required with constant

Rain rate, mm/h. Finite, at least 0. Only with constant.

flume.rain.file

string

required with hyetograph or gridded

Hyetograph file (Hyetograph files) or index of rain grids (Gridded rain index files). Only with hyetograph or gridded.

flume.rain.interpolation

string

step

step holds each rate (or grid) until the next time; linear interpolates in time. Only with hyetograph or gridded.

flume.rain.cell.peak_rate

real

required with moving_cell

Rate at the centre of the cell, mm/h. Finite, at least 0.

flume.rain.cell.sigma

real

required with moving_cell

Standard deviation of the Gaussian, m. Finite, above 0.

flume.rain.cell.center

2 reals

required with moving_cell

Centre at \(t = 0\), m, in the coordinates of flume.prob_lo. Both finite.

flume.rain.cell.velocity

2 reals

0 0

Velocity of the centre, m/s. Both finite. A step over which the centre moves more than 2500 sigma stops the run. The step bound stays the peak rate after the cell has left the domain, so a dry run needs flume.stop_time or flume.max_step.

Each flume.rain.cell.* key is allowed only with moving_cell; flume.rain.file and flume.rain.interpolation are not allowed with it.

Infiltration

The models are in Infiltration. Each soil parameter is one value for every cell or an ESRI ASCII grid (_file; each cell takes the raster cell that holds its centre, and every cell of the domain must take a value in the range), not both. A parameter is required with its model and allowed only with it. Building cells (flume.buildings.file) infiltrate nothing.

Key

Type

Default

Meaning and allowed values

flume.infiltration.type

string

none

none, green_ampt or curve_number. curve_number needs rain (flume.rain.type).

flume.infiltration.green_ampt.conductivity, _conductivity_file

real or string

required with green_ampt

Saturated hydraulic conductivity \(K_s\), mm/h. Finite, at least 0; 0 is impervious.

flume.infiltration.green_ampt.suction, _suction_file

real or string

required with green_ampt

Suction head at the wetting front \(\psi_s\), mm. Finite, at least 0.

flume.infiltration.green_ampt.deficit, _deficit_file

real or string

required with green_ampt

Initial moisture deficit \(\theta_d\), the porosity less the initial moisture content (a fraction). Finite, from 0 to 1.

flume.infiltration.cn.number, _number_file

real or string

required with curve_number

Runoff curve number \(CN\). Finite, above 0 and at most 100; 100 is impervious. It must match ia_ratio (see below).

flume.infiltration.cn.ia_ratio

real

0.2

Initial abstraction ratio \(\lambda = I_a / S\). Finite, at least 0 and below 1. Only with curve_number.

Initial state

Without flume.init.surface_elevation the domain starts dry (Initial state).

Key

Type

Default

Meaning and allowed values

flume.init.surface_elevation

real

none

Elevation of the initial level surface. Finite. Cells whose bed is at or above it start dry.

flume.init.velocity

2 reals

0 0

Initial velocity where there is water, m/s. Finite. Needs flume.init.surface_elevation.

flume.init.dam_position

real

none

Coordinate of a dam along flume.init.dam_direction. Finite, with a cell centre on each side. Needs flume.init.dam_surface_elevation.

flume.init.dam_surface_elevation

real

none

Surface elevation in the cells whose centre is at or above the dam position. Finite. Required with a dam.

flume.init.dam_velocity

2 reals

flume.init.velocity

Velocity on the high side of the dam, m/s. Finite. Needs a dam.

flume.init.dam_direction

x or y

x

Direction the dam position is measured along. Needs a dam.

flume.init.surface_slope

2 reals

0 0

Slope of the initial surface about the centre of the domain. Finite. Not with a dam. For tests.

flume.init.surface_curvature

real

0

Curvature of the initial surface about the centre, 1/m. Finite. Not with a dam. For tests.

flume.init.wave_amplitude

real

0

Amplitude of one sine wave of the depth, with the velocity of a simple wave. Finite. Needs a periodic direction along the wave; not with a dam, a surface slope or a curvature. For tests.

flume.init.wave_direction

x or y

x

Direction the wave varies along. Needs a wave.

Checks

  • A key given the wrong number of values stops the run.

  • A value of the wrong type, or a key with no value, is stopped by AMReX’s parser; its message may not name the key. The parser accepts expressions: 1e3 is a valid integer.

  • A key in another namespace that nothing reads stops the run when it ends, after the output is written (amrex.abort_on_unused_inputs, which FLUME turns on; = 0 turns it off).

  • The bed and the initial state must be finite in every cell.

  • Before every step and every plotfile the depth must be finite and not negative.

  • The time step must be finite, above zero and large enough to change the time.

  • A dry domain with flume.max_step alone and no rain ahead stops with a message asking for flume.stop_time (Dry domain).

The integer keys have no joint limit on the number of boxes: a very large flume.n_cell with a small flume.max_grid_size can ask for more boxes than memory holds.