Verification
Each case below is a CTest regression test that compares a run with a closed form. The numbers are what the runs give in double precision; the tests bound them slightly above. Test catalogue lists every test.
Lake at rest
A level surface over a rough bed (a plane moved by up to 0.5 m in every
cell), between walls, for 50 steps (Tests/LakeAtRest). Depth and
discharges stay at their initial values within 16 machine epsilons of the
surface elevation, at both orders, with dry islands, with a dry depth of
0.05 m, with outflow segments, with Manning friction, and over raster
buildings. Without the bed-slope term of the hydrostatic reconstruction the
discharges reach 1 m2/s.
Dam break
Still water 2 m deep on one side of a dam, on a flat bed, 400 cells of
0.25 m, compared at 5 s with the exact solutions of Delestre et al. (2013,
sections 4.1.1 and 4.1.2) (Tests/DamBreak).
Wet bed (1 m on the low side). The solution is a rarefaction, a constant state \((h_m, u_m)\) and a shock of speed \(S\):
with \(h_1\), \(h_0\) the deep and shallow depths. Here \(h_m\) = 1.4538 m, \(u_m\) = 1.3058 m/s, \(S\) = 4.1831 m/s.
Dry bed. Ritter’s solution; the front has run 44.3 m at 5 s.
Case |
Depth, order 1 |
Discharge, order 1 |
Depth, order 2 |
Discharge, order 2 |
|---|---|---|---|---|
Wet bed |
0.80 % |
1.59 % |
0.24 % |
0.50 % |
Dry bed |
0.46 % |
0.39 % |
0.13 % |
0.12 % |
Dry bed, outflow side, 9 s |
0.45 % |
0.30 % |
0.10 % |
0.07 % |
Wet bed, outflow side, 10 s |
0.67 % |
1.21 % |
0.20 % |
0.32 % |
On the wet bed the constant state is within 0.19 % (order 1) and 0.03 % (order 2), and the shock within 0.2 and 0.1 cell of its place. Mass is conserved to 16 machine epsilons. On the dry bed no depth is negative and no water lies beyond the exact front; the thin front of the first-order run lags the exact one, the depth passing 1 mm about 7 m behind it.
The first step of the dry-bed run has a closed form, which pins the dry-bed
wave speeds: with flume.cfl = 0.5 the first dry cell ends 1/3 m deep and
the last wet cell 5/3 m deep, within 64 machine epsilons.
With the outflow side the dry-bed front leaves supercritical and Ritter’s solution still holds. On the wet bed the flow behind the shock is subcritical, and the wave the side sends back (Boundary conditions) leaves the constant state 0.17 % low in depth and 0.28 % high in velocity at first order, 0.68 % and 1.97 % at second order.
Thacker’s solutions in a bowl
Water in a paraboloid bowl (\(h_0\) = 0.1 m, \(a\) = 1 m) with a
shoreline moving over the dry bed, compared with the solutions of Delestre
et al. (2013, section 4.2.2) (Tests/Bowl). With \(X\), \(Y\)
measured from the centre and \(z = -h_0 (1 - r^2 / a^2)\):
Planar (a plane surface that turns about the axis; \(\eta\) = 0.5 m, period 4.4857 s):
Radial (a paraboloid surface that rises and falls; \(r_0\) = 0.8 m, period 2.2429 s), with \(A = (a^2 - r_0^2) / (a^2 + r_0^2)\) and \(D = 1 - A \cos\omega t\):
Run |
Cells |
Depth, order 1 |
Discharge, order 1 |
Depth, order 2 |
Discharge, order 2 |
|---|---|---|---|---|---|
Planar, half a period |
100 x 100 |
13.5 % |
19.7 % |
1.71 % |
2.12 % |
Planar, half a period |
200 x 200 |
7.3 % |
10.8 % |
0.61 % |
0.71 % |
Planar, three periods |
100 x 100 |
56.5 % |
76.8 % |
3.67 % |
5.56 % |
Radial, half a period |
100 x 100 |
4.2 % |
2.8 % |
1.02 % |
0.71 % |
Radial, half a period |
200 x 200 |
2.2 % |
1.8 % |
0.29 % |
0.20 % |
Radial, three periods |
100 x 100 |
20.7 % |
4.5 % |
3.80 % |
1.54 % |
The first-order scheme damps the motion; its error halves with the cell size. At second order the error falls by 2.8 (planar) and 3.5 (radial) when the cell size is halved, rates of 1.5 and 1.8. In every run no depth is negative and mass is conserved to 64 machine epsilons.
Simple wave: rate of convergence
One sine wave of 0.1 m on water 1 m deep over a flat bed, 10 m long and
periodic, in water moving at (0.5, -0.3) m/s, compared at 1 s with the exact
solution (Tests/Wave). The depth at \(x\) at time \(t\) is the
initial depth at \(x_0\), where
The solution is smooth until 3.2 s.
Run |
Cells along |
Steps |
Depth |
Discharge |
|---|---|---|---|---|
Order 1, x |
100 |
154 |
0.0353 |
0.0408 |
Order 2, x |
100 |
154 |
0.00350 |
0.00413 |
Order 2, x |
200 |
307 |
0.00094 |
0.00111 |
Order 2, x |
400 |
614 |
0.00025 |
0.00030 |
Order 2, y |
100 |
142 |
0.00271 |
0.00252 |
Order 2, y |
200 |
283 |
0.00073 |
0.00068 |
Order 2, x, cells 250 m wide |
100 |
82 |
0.00364 |
0.00428 |
The second-order error falls by 3.7 each time the cell size is halved, a rate of 1.9; the minmod limiter keeps it below 2. The first-order run is ten times further from the solution on the same cells.
Uniform flow with friction
Water 1 m deep starts at rest in an endless channel that falls by 1 mm per
metre, with \(n\) = 0.03 s/m1/3 (Tests/Friction). The depth
stays 1 m and the discharge follows
with \(q_n\) = 1.05409 m2/s and \(T_r\) = 107.451 s.
Run |
Order 1 |
Order 2 |
|---|---|---|
Transient, 100 s |
5.64e-4 |
1.66e-4 |
Transient, 100 s, half the step |
8.31e-5 |
|
Steady, 1500 s |
2.50e-4 |
1.2e-13 |
Thin film: 1 mm on a slope of 0.1, \(n\) = 0.05, 10 s |
1.1e-9 |
|
Manning map, one coefficient per row (0.02 to 0.06) |
5.63e-4 |
1.91e-4 |
The steady error at first order is the bias of the first-order bed-slope term, \(1 - \sqrt{1 - S \Delta x / (2 h)}\) = 2.50031e-4 (Manning friction). The transient error halves with the step: friction is first order in time. In the thin film the friction time is 0.0645 s and the step about 2 s; an explicit friction term would reverse the discharge.
Rain on a plane: kinematic wave
Rain of \(i\) = 50 mm/h on a dry, impermeable plane 100 m long, falling
at \(S_0\) = 0.01 to an outflow side, with \(n\) = 0.01
s/m1/3 (Tests/Rain/inputs_plane). With
\(\alpha = S_0^{1/2} / n\) the kinematic-wave solution is
The plane reaches equilibrium at 349 s, with 4.8 mm at the outlet and a Froude number of 1.3.
Order, cell, CFL |
Depth, L1 |
Outlet discharge |
|---|---|---|
1, 0.2 m, 0.5 |
10.2 % |
11.1 % |
1, 0.1 m, 0.5 (test) |
5.5 % |
5.7 % |
2, 0.2 m, 0.5 |
2.8 % |
3.6 % |
2, 0.1 m, 0.5 |
1.2 % |
2.6 % |
2, 0.1 m, 0.125 (test) |
0.22 % |
1.3 % |
At order 1 the error falls with the cell size and is largest at the upstream end, where the film is thinner than the bed step of a cell (Hydrostatic reconstruction). At order 2 and CFL 0.5 the error is mostly that of friction acting once per step, which halves with the step. At order 1 the outlet discharge at equilibrium equals \(i L\) to round-off.
A coarser set-up (1 m cells, \(n\) = 0.03) is outside what the scheme resolves: the bed falls by more than the film depth per cell (depth error 27 % at equilibrium) and the outflow is subcritical.
Rain volume
Rain on a closed, flat, dry domain (Tests/Rain/inputs_flat): every cell
holds the rain fallen by the plotfile’s time, equal to the last bit in
double precision, for a constant rate and for step and linear hyetographs.
On 1 m of still water, rain of 0.36 mm/h (1.6e-8 m per step) is kept in
single precision by the compensated sum. In a closed basin with moving
water the volume grows by the rain fallen (8.9e-13 of an added 6.4e-3).
Rain that varies in space (Tests/RainField/inputs_flat, 24 by 16 cells
of 2 m in 6 boxes), against a reference computed from the files:
Case |
Largest difference |
|---|---|
Every cell, one step, grids of 3.7 by 2.9 m, linear in time |
9.9e-16 of the largest depth |
Every cell, one step, grid of 1.3 m |
4.3e-16 |
Every cell, 1 m grid on solver edges, NODATA ring outside |
17 eps |
Water to 1200 s, three grids, step and linear |
7.1e-16 of the water (3 eps) |
Moving cell at rest, every cell |
5.8e-16 |
Moving cell, 29 m in one step (20 sub-intervals) |
1.1e-13 (1.3e-2 with one) |
Moving cell leaving the domain, water to 1200 s |
1.4e-16 |
Infiltration
Closed, flat domains where every cell is the same, against the closed forms
of Infiltration (Tests/Infiltration). Soil parameters from
Rossman and Huber (2016, Table 4-7).
Case |
Largest difference |
|---|---|
Green-Ampt, 0.5 m ponded on silt loam, 6 h, 4506 steps |
2.9e-11 m (a time shift of 3.7e-6 s) |
Green-Ampt, 36 mm/h on dry sandy loam, 2 h |
7.6e-17 m |
Curve number 75, 36 mm/h, 2 h (72 mm, loss 50.30 mm) |
1.4e-17 m |
Curve number 65.31 with \(\lambda = 0.05\) |
1.4e-17 m |
Curve-number map with flow and buildings, per cell |
3.5e-18 m |
The ponded case differs only by a shift in time: the first step takes the ponded water as rain and saturates the surface after \(K_s M \Delta t^2/h^2 \approx 7.5 \times 10^{-6}\) s, where exact ponding takes half that, so \(F\) lags by \(K_s M \Delta t^2/(2h^2) \approx 3.7 \times 10^{-6}\) s; from there the integrated equation is exact. In every case with a closed form, the depth plus the infiltrated depth of each cell is the water it got to 4 machine epsilons, also over the 279217 steps of a curve-number run on 2 cm cells. On a sloped, walled domain with a hyetograph, a conductivity map and buildings (second order, 3 ranks), the water on the surface plus the infiltrated water equals the rain to \(5.7 \times 10^{-14}\) of 28.8 m3 per m2 of cell.
Partial outflow
The dry-bed dam break on 200 by 40 cells, with the side ahead an outflow over half its length and a wall over the rest. In the open rows the L1 error against Ritter’s solution is 0.75 % (order 1) and 0.20 % (order 2) of the depth. In the wall rows the depth at the wall is within 4.3 % of the bore depth from the jump conditions.
Rasters
A bed raster holding \(z = 2 + 0.03 x - 0.02 y + 0.001 x y\) at the
centres of 5 m cells is reproduced on 1 m cells to 8.9e-16 m
(Tests/Raster). A dam break through streets between raster buildings 3
to 8 m high keeps every building cell dry and conserves mass to 64 machine
epsilons; with the buildings 0.3 m high the water goes over them and mass is
conserved.
Decomposition
Runs on 1, 2 and 4 ranks, in boxes down to one cell wide, give the same cells. An outflow side given as one segment or as two that meet inside a box gives plotfiles identical to the last bit.