Boundary conditions
Each direction is periodic or not (flume.periodic). The state and the
bed carry one layer of ghost cells at first order and two at second order.
A side that is not periodic is made of segments (flume.bc.segments),
each a run of boundary cells with one type. A boundary cell belongs to a
segment when its centre is at the first coordinate of
flume.bc.<name>.range or above, and below the second. Cells no segment
covers are walls.
Type |
Ghost cells |
|---|---|
|
Mirror the cells inside: same depth, bed and tangential discharge; normal discharge with its sign changed. The mass flux through a wall is exactly zero. |
|
Take the boundary cell next to them, the bed included (zero gradient). Nothing is prescribed. |
periodic |
Take the cell they cover. |
discharge and stage are reserved for a prescribed inflow and a
prescribed water level.
Outflow
Where the flow leaving is supercritical the side sets nothing the flow inside depends on. Where it is subcritical, zero gradient is an approximation, with two limitations:
A shock that leaves sends a weak wave back. In the dam-break test it changes the depth by 0.2 % and the velocity by 0.3 % at first order, and by 0.7 % and 2 % at second order. It does not shrink with the cell size.
Still water next to an outflow side is not stable where the bed of the boundary cell is lower than that of the cell inside it: a disturbance grows from round-off over thousands of steps (up to 9 % per step over a rough bed in a 1-D model of the scheme). Runs whose water comes to rest against an outflow side over a bed that steps down to the side should not stay long in that state.
Periodic sides and a sloping bed
By default the bed repeats across a periodic side, with a step of the slope
times the length of the domain. With flume.bed.continue_slope = 1 the
ghost cells take the bed of the cell they cover plus the slope times the
distance between the two: an endless inclined channel. The depth and the
discharges still repeat. Only the plane is continued, not a bowl or a