Running
FLUME reads an AMReX inputs file, given as the first argument. Keys can be added or overridden on the command line:
mpiexec -n 4 ./flume inputs flume.max_grid_size=32
A first case
Tests/DamBreak/inputs holds still water 2 m and 1 m deep on the two sides
of a dam, on a flat bed between walls:
flume.n_cell = 400 4
flume.prob_hi = 100.0 1.0
flume.max_grid_size = 64
flume.plot_file = dam
flume.stop_time = 5.0
flume.init.surface_elevation = 2.0
flume.init.dam_position = 50.0
flume.init.dam_surface_elevation = 1.0
mpiexec -n 2 build-rel/flume Tests/DamBreak/inputs flume.order=2
The run writes dam00000 (initial state) and the plotfile of the last
step. Verification compares this case with its exact solution.
A flood case adds a bed raster, buildings, friction and rain:
flume.n_cell = 400 300
flume.prob_lo = 500000 4100000
flume.prob_hi = 502000 4101500
flume.stop_time = 3600
flume.order = 2
flume.plot_int = 500
flume.bed.file = bed.asc
flume.buildings.file = buildings.asc
flume.friction.manning_file = manning.asc
flume.rain.type = hyetograph
flume.rain.file = storm.txt
flume.bc.segments = outlet
flume.bc.outlet.side = xhi
flume.bc.outlet.type = outflow
Inputs lists every key and Input files the file formats.
How a run ends
The run stops at flume.stop_time or after flume.max_step steps,
whichever comes first. With neither key it writes the initial state and takes
no step. The last step ends exactly on flume.stop_time.
The run stops with a message naming the input when a key is unknown, out of range or inconsistent with another, and when a depth becomes negative or not finite (Checks).
Output
The run writes AMReX plotfiles named <prefix><step>, with the step in at
least five digits: the initial state, every flume.plot_int steps, and the
last state. An existing plotfile of the same name is first renamed to
<prefix><step>.old.<number>.
Variable |
Unit |
Meaning |
|---|---|---|
|
m |
Water depth, \(h\). |
|
m2/s |
Discharge per unit width in x, \(hu\). |
|
m2/s |
Discharge per unit width in y, \(hv\). |
|
m |
Bed elevation on the vertical datum, \(z_b\), buildings included. |
|
m |
Water-surface elevation, \(z_b + h\); the bed elevation in a dry cell. |
|
m |
Depth of water each cell has lost to the soil since the start
(Infiltration). Written only with
|
The plotfile is three-dimensional with one cell in z, from 0 to 1 m; the z extent carries no meaning. ParaView, VisIt and yt read the format.
The log reports, at start-up, the boundary cells of each segment, the active source terms, the rain, the infiltration parameters, the range of the Manning map and the number of building cells.