Running

FLUME reads an AMReX inputs file, given as the first argument. Keys can be added or overridden on the command line:

mpiexec -n 4 ./flume inputs flume.max_grid_size=32

A first case

Tests/DamBreak/inputs holds still water 2 m and 1 m deep on the two sides of a dam, on a flat bed between walls:

flume.n_cell        = 400 4
flume.prob_hi       = 100.0 1.0
flume.max_grid_size = 64
flume.plot_file     = dam
flume.stop_time     = 5.0

flume.init.surface_elevation     = 2.0
flume.init.dam_position          = 50.0
flume.init.dam_surface_elevation = 1.0
mpiexec -n 2 build-rel/flume Tests/DamBreak/inputs flume.order=2

The run writes dam00000 (initial state) and the plotfile of the last step. Verification compares this case with its exact solution.

A flood case adds a bed raster, buildings, friction and rain:

flume.n_cell    = 400 300
flume.prob_lo   = 500000 4100000
flume.prob_hi   = 502000 4101500
flume.stop_time = 3600
flume.order     = 2
flume.plot_int  = 500

flume.bed.file                = bed.asc
flume.buildings.file          = buildings.asc
flume.friction.manning_file   = manning.asc

flume.rain.type = hyetograph
flume.rain.file = storm.txt

flume.bc.segments   = outlet
flume.bc.outlet.side = xhi
flume.bc.outlet.type = outflow

Inputs lists every key and Input files the file formats.

How a run ends

The run stops at flume.stop_time or after flume.max_step steps, whichever comes first. With neither key it writes the initial state and takes no step. The last step ends exactly on flume.stop_time.

The run stops with a message naming the input when a key is unknown, out of range or inconsistent with another, and when a depth becomes negative or not finite (Checks).

Output

The run writes AMReX plotfiles named <prefix><step>, with the step in at least five digits: the initial state, every flume.plot_int steps, and the last state. An existing plotfile of the same name is first renamed to <prefix><step>.old.<number>.

2 Plotfile variables

Variable

Unit

Meaning

depth

m

Water depth, \(h\).

discharge_x

m2/s

Discharge per unit width in x, \(hu\).

discharge_y

m2/s

Discharge per unit width in y, \(hv\).

bed_elevation

m

Bed elevation on the vertical datum, \(z_b\), buildings included.

surface_elevation

m

Water-surface elevation, \(z_b + h\); the bed elevation in a dry cell.

infiltrated_depth

m

Depth of water each cell has lost to the soil since the start (Infiltration). Written only with flume.infiltration.type other than none.

The plotfile is three-dimensional with one cell in z, from 0 to 1 m; the z extent carries no meaning. ParaView, VisIt and yt read the format.